SLP 4 Series
Wave ID and Set Reference
The SLP4-6D test kit combines the OPM4-4D optical power meter and OLS2-Dual LASER light source and is ideally
suited for testing single-mode fiber optic networks.
The SLP4 triple wavelength single-mode test kits are available in two models, SLP4-FTTH and SLP4-7. The SLP4-
FTTH and SLP4-7 model combine the OPM4-4D optical power meter and either OLS7-FTTH (1310/1490/1550 nm)
or OLS7-3 (1310/1550/1625 nm) LASER source respectively.
SLP 5 Series
Wave ID, Set Reference and Data Storage
The SLP5-6D test kit combines the OPM5-4D optical power meter and OLS2-Dual LASER light source and is ideally
suited for testing single-mode fiber optic networks.
The SLP5 triple wavelength single-mode test kits are available in two models, SLP5-FTTH and SLP5-7. The SLP5-
FTTH and SLP5-7 model combine the OPM5-4D optical power meter and either OLS7-FTTH (1310/1490/1550 nm)
or OLS7-3 (1310/1550/1625 nm) LASER source respectively.
OLTS 5
Bi-Direction, Dual-Wavelength Testing Capabilities
The OLTS 5 may be operated in automatic or manual test modes. In its “two-unit automatic test mode, a pair of
OLTS 5 test sets may be used to measure the end-to-end, bi-directional insertion loss of a pair of single-mode fibers
at 1310/1550nm or 1550/1625 nm. Tests are started and controlled by the user from the OLTS 5 configured as the
Main unit. Test progress messages and results are displayed on the Remote unit. Full test results can be reviewed
and saved in the Main unit. Thresholds may be set to provide Pass/Fail results.
In its “single-unit” automatic test mode the OLTS 5 can measure bi-directional, dual-wavelength insertion loss of
patch cords, or fiber optic cables while they are still on the reel.
In the manual operating mode individual OLTS 5 test sets can operate either as an optical power meter (OPM) or
dual-wavelength laser source.
The OLTS 5 can store dual-wavelength, bi-directional insertion loss results for up to 1,000 fibers. Test results can be
organized in up to 20 user-named files. Results are transferred to a PC via a serial link. Windows® software is provided
to view, edit, and print test results.
OLTS 5 units are sold individually but normally used in pairs.
CONTACT INFO
Email: sales@focenter.com / On the web: www.focenter.com / Telephone: 1-800-IS-FIBER (800) 473-4237
Specifications may change without notice
HAND-HELD OPTICAL MEASUREMENT DEVICES / G-2
Noyes Single Mode Optical Loss Test Sets
TEST & INSPECTION
Seitenansicht 131
1 2 ... 127 128 129 130 131 132 133 134 135 136 137 ... 153 154

Kommentare zu diesen Handbüchern

Keine Kommentare